SPON COMMUNICATIONS: BLAZING A TRAIL IN INNOVATIVE IP PA SYSTEM DESIGNS

SPON Communications: Blazing A Trail in Innovative IP PA System Designs

SPON Communications: Blazing A Trail in Innovative IP PA System Designs

Blog Article

Network PA System for tool to large-scale projects



Introduction


The XC-9000 system is a fully digital network PA system based upon the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes sure the reliable and correct transmission of all data packets. Not only can it use existing local area network, such as LANs or the Web, to transfer broadcast signals, however additionally it can likewise be deployed on a committed broadcasting network.


A single-server system can sustain up to 3000 terminals and permits for server cascading. There are no constraints on the concurrent broadcast channels, accomplishing true full electronic broadcasting.


System Qualities



Versatile PA System Design


The PA system style is basic, including service management software, network microphones, network amplifiers, network audio speakers, and various other devices.All equipment is connected using the TCP/IP intranet procedure, enabling versatile setup and simple management of the system, with totally free control over broadcast content, network devices, and areas with the network.


Spon CommunicationsIp Pa System
Comprehensive Sound Management


The audio monitoring software application consists of built-in functions for producing program plans, adaptable zoning, and pre-scheduled broadcasts.It supports 24-hour programs, permitting for transforming setups during throughout the day


Versatile Sound Source Support


The system supports different types of audio sources for sending alerts like live speech and BGM playback. Sound sources can originate from digital music applications, CD/DVD gamers, microphones, etc. On top of that, the system offers diverse features of supporting different broadcasting functions such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Combination


The system has a fire alarm system feature and can be integrated right into an emergency alarm system. When the alarm central system obtains the disconcerting signals, the cable will certainly transmit the signal to gadgets, which causes the XC-9000, sending signals to speakers


Users might pick to preset settings to trigger full-area or zoned alarms in emergencies. The alarm voices can be found in numerous forms and could be modified accommodating needs. For instance, individuals can transform language setups, upload and edit their audio sources according to precise needs, such as intruding alarms, smoke alarm or air help alarm systems, and so on





Fire Alarm System Assimilation


The system has a smoke alarm function and can be integrated into an emergency alarm system. When the alarm system main unit receives the disconcerting signals, the cable will certainly send the signal to tools, which causes the XC-9000, sending signals to audio speakers


Customers can pick to pre-programmed setups to turn on full-area or zoned alarm systems in emergencies. The alarm system voices can be found in several kinds and might be modified accommodating requirements. Users can alter language settings, upload and edit their audio sources according to exact demands, such as intruding alarm systems, fire alarms or air aid alarm systems, etc.


Application Control for System Procedures


The system allows mobile application login and use, allowing individuals to initiate programs and other operations to authorized terminals through the server software, guaranteeing a streamlined and hassle-free experience.


Integrated SIP Compatibility


The system not only allows SIP phones to log in, but additionally can be linked to third-party SIP web server or IPPBX, which develops a completely integrated and suitable communication system through smooth integration right into existing systems.


Open SDK


When huge job like clever park takes place, the system gives an open SDK incorporated into third-party application systems - IP Paging Microphone


System Facilities



Main Features


Scheduled Playback


The system is able to instantly transmit according to the scheduled jobs as long as individuals publish the audio declare each period of the day to the web server and develop a playback routine.


Area Broadcasting


The system can arbitrarily separate a few network gadgets into various areas to play specified audio programs or send announcements to any type of designated location. The quantity of each device can be from another location adjusted.


Real-time Broadcasting


The system can transmit and record radio programs or other outside audio resources in real-time, and at the same time transmitted them in sync.


Fire Alarm Combination


The system can be incorporated with the emergency alarm system for control. When a fire alarm signal is caused, it automatically triggers the emergency situation broadcast function and sustains surrounding floor alarms. It additionally permits hands-on emergency situation broadcasting by clicking a solitary button.


SIP Phone Integration


The system can be incorporated with SIP web servers, permitting live speech of voice broadcasting through SIP phones to send statements anytime and anywhere.


CCTV Combination


The electronic tools such as IP POE Audio speakers embraces the global basic ONVIF procedure, which allows their voices to be transmitted through VMS systems. The terminals can additionally be incorporated with CCTV systems for integrated program.


Main Products



Audio Administration Software XC-9000


B/S architecture, sustains cross-platform applications.
Covers traditional broadcasting system functions, enabling partition administration.
Unified administration of terminals within the system, watching job standing, and set volume modification, etc.
Supports building multi-level server styles, deploying administration according to customer geographical regions.
Supplies SDK advancement bundles for second advancement and combination with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * great site 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 18KHz.
Intercom: Supported, Integrated Microphone.
Running Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Surface Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Reaction: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Reaction: 50Hz~ 20KHz.
Operating Temperature: -10~ 55 ℃.
Dimensions: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 60Hz~ 18KHz.
Running Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Feedback :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Method: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm outcomes.
Operating Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Solution For Institution





Adaptable Zoning Program:


The totally network terminals can understand versatile zoning alternatives, permitting broadcasting alerts to specific terminals or different zones ( gadgets).


Institution Bell System:


It provides school bell system at the beginning/ending of the course - IP Speaker. Numerous situations can be created, consisting of different scheduled program tasks according to summer/winter timetable


Fire Alarm Combination


It supports assimilation with smoke alarm systems, allowing emergency alarm signals to be incorporated right into the PA system.


Classroom Audio Boosting


Terminals support daily applications in class scenes. They can be linked to projectors or interactive white boards for audio boosting.


Ip Paging MicrophoneSpon Communications

Smart Street Lamp/Security Pole



Support SIP Protocol:


Integrated SIP method for smooth integration with network interaction systems.


VMS Platforms Integration:


Integrated ONVIF protocol for integration with VMS systems.


Third-Party Assimilation:


Integrated In HTTP API for assimilation look these up with 3rd party platforms.


Voice Alarm Activating:


Developed in alarm input user interface for triggering voice alarm systems with video cameras.


Service For Hotel



Zone Control by Flooring:


The system provides full network settings, splitting areas depending on various floors and control Recommended Reading over each area individually.


Emergency Alarm Integration:


The system can be incorporated with emergency alarm system, allowing combination of emergency alarm signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable set up broadcasting, allowing adaptable plans according to various requirements.


Emergency situation Broadcasting:


It sustains emergency broadcasting for the whole area, making it possible for one-click emergency situation communication.


Option For Manufacturing facility



Zone Broadcasting:


It permits broadcasting to any type of zone, assuring no interference between various locations.


Alarm Triggering:


Terminals have various type of user interfaces, enabling to cause alarm systems when gotten in touch with cams.


All Network Instruments:


Release of totally network tools substantially lowers the trouble of operating such as checking gadgets on dangerous sites, and thus safeguarding people and property.


The release of all network gadgets substantially reduces the difficulty of procedure and upkeep monitoring


Integrated SIP Phones:


The system can be incorporated with SIP phone and broadcast notices utilizing SIP phones any time and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it very easy for inspecting tools being in workplace or other workplaces.


The XC-9000 system is a fully electronic network PA system based on the TCP/IP procedure. By leveraging the TCP/IP protocol, the system makes certain the right and reliable transmission of all data packets. The system supports numerous types of audio resources for sending notices like live speech and BGM playback. In enhancement, the system offers diverse functions of supporting various broadcasting features such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page